pCi/L vs Bq/m³: How to Convert Radon Units
Free toolRadon Test Result InterpreterEnter your result in pCi/L or Bq/m³ and see where it falls under EPA guidance, EPA's recommended next step for your type of test, and WHO's reference levels shown separately.Interpret my result →pCi/L vs Bq/m³ is a question of units, not of different radon. In the U.S., radon in air is commonly expressed in picocuries per liter (pCi/L); in western Europe it is given in becquerels per cubic meter (Bq/m³).[EPA] EPA’s technical risk assessment gives the conversion: 1 pCi/L corresponds to 37 Bq/m³.[EPA] This page shows how to convert, why EPA’s consumer pages show slightly different numbers, and where the third unit, working levels (WL), fits.
The conversion factor: 1 pCi/L = 37 Bq/m³
A becquerel (Bq) is one nuclear disintegration per second. By definition, 1 picocurie equals 0.037 Bq, so 1 pCi/L corresponds to 37 Bq/m³.[EPA] This is from EPA’s Assessment of Risks from Radon in Homes (EPA 402-R-03-003, June 2003, reissued with a June 2025 cover).[EPA] EPA’s 1999 proposed rule on radon in drinking water gives the same relationship from the other direction: one pCi is equal to 0.037 Bq, and one Bq is equal to 27 pCi.[U.S. Environmental Protection Agency] (The 27 is 1 divided by 0.037, rounded; it is the same relationship as 37, seen from the other side.)
How to convert
The radon level interpreter accepts either unit.
Worked examples using figures EPA publishes: 10 pCi/L times 37 is 370 Bq/m³, and 20 pCi/L times 37 is 740 Bq/m³; EPA’s risk table lists exactly those pairs.[EPA]
Why EPA pages show 4 pCi/L as 150 Bq/m³
EPA’s consumer pages print a Bq/m³ figure next to each pCi/L value, but several are rounded. The action level is the clearest case: EPA’s FAQ pairs 4 pCi/L with 150 Bq/m³.[EPA] Using the exact factor, 4 times 37 comes out slightly under 150. The difference is small, and the EPA action level itself is stated in pCi/L.[EPA]
The table lists the pairs EPA publishes and how each compares with the exact factor of 37.
| pCi/L | Bq/m³ as EPA prints it | Compared with pCi/L × 37 | Source |
|---|---|---|---|
| 0.4 (average outdoor level) | 15 | Rounded; the exact value is slightly lower | [EPA] |
| 1.3 (average indoor level) | 50 | Rounded; the exact value is slightly lower | [EPA] |
| 2 (start of EPA’s “consider fixing” range) | 75 | Rounded; the exact value is slightly lower | [EPA] |
| 4 (EPA action level) | 150 | Rounded; the exact value is slightly lower | [EPA] |
| 8 | 300 | Rounded; the exact value is slightly lower | [EPA] |
| 10 | 370 | Matches exactly | [EPA] |
| 20 | 740 | Matches exactly | [EPA] |
If your report is in Bq/m³, EPA gives its guidance directly in that unit. Its working-levels FAQ says any radon level at or above 150 Bq/m³ should be reduced,[EPA] and its action-level FAQ gives the “consider fixing” range as 75 - 150 Bq/m³.[EPA] Compare a Bq/m³ result with those published figures. Converting with the factor of 37 is useful for information,[EPA] but a result just under 150 Bq/m³ converts to a little over 4 pCi/L, because EPA’s 150 is rounded; our radon level interpreter places Bq/m³ results with EPA’s Bq/m³ figures for that reason.
WHO reference levels in both units
WHO states its reference levels in Bq/m³. They are WHO recommendations, not EPA guidance, and are kept separate here.
| WHO reference level (WHO’s figure) | EPA’s pCi/L equivalent | Compared with ÷ 37 |
|---|---|---|
| 100 Bq/m³[World Health Organization] | 2.7 pCi/L[EPA] | Matches, rounded to one decimal place |
| 300 Bq/m³, the upper limit if 100 Bq/m³ cannot be reached[World Health Organization] | 8.1 pCi/L[EPA] | Matches, rounded to one decimal place |
Note that EPA prints 8 pCi/L as 300 Bq/m³ in its risk table[EPA] and 300 Bq/m³ as 8.1 pCi/L in its WHO FAQ[EPA]; both are rounded, in different directions. Elsewhere in that WHO FAQ, one sentence pairs the WHO pCi/L range with a different Bq/m³ range[EPA]; use WHO’s own 100 and 300 Bq/m³.[World Health Organization]
EPA says the WHO recommendation does not directly affect its 4 pCi/L action level.[EPA] How the two compare is covered on EPA radon action level.
The third unit: working levels (WL)
Some reports give working levels. EPA’s risk assessment explains that radon progeny (decay product) concentrations are commonly expressed in WL.[EPA] EPA says radon test results may be reported in pCi/L, WL or Bq/m³, and that if your result is in WL, EPA recommends fixing your home at 0.016 WL or higher. Some states require WL results to be converted to pCi/L to minimize confusion.[EPA]
EPA’s risk assessment explains that each pCi/L of radon gives rise to almost precisely 0.01 WL only under equilibrium conditions, that ordinarily these conditions do not hold, and that in homes the equilibrium fraction is typically 40%.[EPA] Use EPA’s stated WL action level rather than converting a WL result yourself.
Reading a radon report in another unit: checklist
- Find the unit on the report: pCi/L, Bq/m³ or WL.[EPA]
- If Bq/m³, compare with EPA’s Bq/m³ figures: at or above 150 Bq/m³ should be reduced;[EPA] consider fixing between 75 and 150 Bq/m³.[EPA] Dividing by 37 gives pCi/L for information.[EPA]
- If pCi/L, compare with EPA guidance in pCi/L: fix at 4 pCi/L or higher (after a follow-up test if your first test was short-term); consider fixing between 2 and 4 pCi/L.[EPA][EPA]
- If WL, compare with EPA’s 0.016 WL, or ask the lab or your state radon office for a pCi/L result.[EPA]
- Keep WHO figures separate from EPA’s: 100 and 300 Bq/m³ are WHO reference levels.[World Health Organization]
- Check which test it was. EPA says a short-term test is less likely than a long-term test to tell you your year-round average.[EPA]
EPA says radon levels less than 4 pCi/L still pose a risk.[EPA] This is general information, not medical advice; talk to your doctor about health questions. For what each level means under EPA guidance, see radon levels.
Frequently asked questions
How do I convert pCi/L to Bq/m³?
Multiply by 37. EPA's Assessment of Risks from Radon in Homes says 1 picocurie equals 0.037 Bq, so 1 pCi/L corresponds to 37 Bq/m³. For example, EPA lists 10 pCi/L as 370 Bq/m³.
How do I convert Bq/m³ to pCi/L?
Divide by 37. EPA gives WHO's 100 Bq/m³ reference level as 2.7 pCi/L and 300 Bq/m³ as 8.1 pCi/L, which matches dividing by 37 and rounding to one decimal place.
Why does EPA say 4 pCi/L is 150 Bq/m³?
EPA's consumer pages show a rounded equivalent. Multiplying 4 by the exact factor of 37 gives a value slightly under 150, and EPA's pages print 150 Bq/m³ next to its 4 pCi/L action level.
Which unit does the EPA action level use?
EPA states its action level in pCi/L: fix your home at 4 pCi/L or higher. Its FAQ pages add 150 Bq/m³ and, for working-level results, 0.016 WL.
Is WHO's 100 Bq/m³ the same as EPA's 4 pCi/L?
No. EPA gives WHO's 100 Bq/m³ reference level as 2.7 pCi/L, which is lower than EPA's 4 pCi/L action level. EPA says the WHO recommendation does not directly affect its action level.
Sources
- U.S. Environmental Protection Agency (EPA), Office of Radiation and Indoor Air. EPA Assessment of Risks from Radon in Homes (EPA 402-R-03-003) — errata, preface, abstract and executive summary. Accessed 2026-11-25.
- U.S. Environmental Protection Agency (EPA), Federal Register via GPO govinfo. National Primary Drinking Water Regulations; Radon-222; Proposed Rule (64 FR 59246, November 2, 1999) — excerpts. Accessed 2026-11-25.
- U.S. Environmental Protection Agency (EPA). What is EPA's Action Level for Radon and What Does it Mean? (EPA Radon FAQ). Accessed 2026-11-25.
- U.S. Environmental Protection Agency (EPA). Health Risk of Radon. Accessed 2026-11-25.
- U.S. Environmental Protection Agency (EPA). Explain Working Levels (WL) and Picocuries Per Liter of Air (pCi/L) (EPA Radon FAQ). Accessed 2026-11-25.
- U.S. Environmental Protection Agency (EPA). Does the 2009 World Health Organization's recommendation of a lower radon action level affect the EPA's radon action level of 4 pCi/L? (EPA Radon FAQ). Accessed 2026-11-25.
- World Health Organization (WHO). Radon (WHO fact sheet). Accessed 2026-11-25.
- U.S. Environmental Protection Agency (EPA), Indoor Environments Division. A Citizen's Guide to Radon: The Guide to Protecting Yourself and Your Family from Radon (EPA 402/K-12/002). Accessed 2026-11-25.
- U.S. Environmental Protection Agency (EPA). What is the average level of radon found in homes in the U.S.? (EPA Radon FAQ). Accessed 2026-11-25.