pCi/L vs Bq/m³: How to Convert Radon Units

Free toolRadon Test Result InterpreterEnter your result in pCi/L or Bq/m³ and see where it falls under EPA guidance, EPA's recommended next step for your type of test, and WHO's reference levels shown separately.Interpret my result →

pCi/L vs Bq/m³ is a question of units, not of different radon. In the U.S., radon in air is commonly expressed in picocuries per liter (pCi/L); in western Europe it is given in becquerels per cubic meter (Bq/m³).[EPA] EPA’s technical risk assessment gives the conversion: 1 pCi/L corresponds to 37 Bq/m³.[EPA] This page shows how to convert, why EPA’s consumer pages show slightly different numbers, and where the third unit, working levels (WL), fits.

The conversion factor: 1 pCi/L = 37 Bq/m³

A becquerel (Bq) is one nuclear disintegration per second. By definition, 1 picocurie equals 0.037 Bq, so 1 pCi/L corresponds to 37 Bq/m³.[EPA] This is from EPA’s Assessment of Risks from Radon in Homes (EPA 402-R-03-003, June 2003, reissued with a June 2025 cover).[EPA] EPA’s 1999 proposed rule on radon in drinking water gives the same relationship from the other direction: one pCi is equal to 0.037 Bq, and one Bq is equal to 27 pCi.[U.S. Environmental Protection Agency] (The 27 is 1 divided by 0.037, rounded; it is the same relationship as 37, seen from the other side.)

How to convert

  1. pCi/L to Bq/m³: multiply by 37.[EPA]
  2. Bq/m³ to pCi/L: divide by 37.[EPA]

The radon level interpreter accepts either unit.

Worked examples using figures EPA publishes: 10 pCi/L times 37 is 370 Bq/m³, and 20 pCi/L times 37 is 740 Bq/m³; EPA’s risk table lists exactly those pairs.[EPA]

Why EPA pages show 4 pCi/L as 150 Bq/m³

EPA’s consumer pages print a Bq/m³ figure next to each pCi/L value, but several are rounded. The action level is the clearest case: EPA’s FAQ pairs 4 pCi/L with 150 Bq/m³.[EPA] Using the exact factor, 4 times 37 comes out slightly under 150. The difference is small, and the EPA action level itself is stated in pCi/L.[EPA]

The table lists the pairs EPA publishes and how each compares with the exact factor of 37.

pCi/L Bq/m³ as EPA prints it Compared with pCi/L × 37 Source
0.4 (average outdoor level) 15 Rounded; the exact value is slightly lower [EPA]
1.3 (average indoor level) 50 Rounded; the exact value is slightly lower [EPA]
2 (start of EPA’s “consider fixing” range) 75 Rounded; the exact value is slightly lower [EPA]
4 (EPA action level) 150 Rounded; the exact value is slightly lower [EPA]
8 300 Rounded; the exact value is slightly lower [EPA]
10 370 Matches exactly [EPA]
20 740 Matches exactly [EPA]

If your report is in Bq/m³, EPA gives its guidance directly in that unit. Its working-levels FAQ says any radon level at or above 150 Bq/m³ should be reduced,[EPA] and its action-level FAQ gives the “consider fixing” range as 75 - 150 Bq/m³.[EPA] Compare a Bq/m³ result with those published figures. Converting with the factor of 37 is useful for information,[EPA] but a result just under 150 Bq/m³ converts to a little over 4 pCi/L, because EPA’s 150 is rounded; our radon level interpreter places Bq/m³ results with EPA’s Bq/m³ figures for that reason.

WHO reference levels in both units

WHO states its reference levels in Bq/m³. They are WHO recommendations, not EPA guidance, and are kept separate here.

WHO reference level (WHO’s figure) EPA’s pCi/L equivalent Compared with ÷ 37
100 Bq/m³[World Health Organization] 2.7 pCi/L[EPA] Matches, rounded to one decimal place
300 Bq/m³, the upper limit if 100 Bq/m³ cannot be reached[World Health Organization] 8.1 pCi/L[EPA] Matches, rounded to one decimal place

Note that EPA prints 8 pCi/L as 300 Bq/m³ in its risk table[EPA] and 300 Bq/m³ as 8.1 pCi/L in its WHO FAQ[EPA]; both are rounded, in different directions. Elsewhere in that WHO FAQ, one sentence pairs the WHO pCi/L range with a different Bq/m³ range[EPA]; use WHO’s own 100 and 300 Bq/m³.[World Health Organization]

EPA says the WHO recommendation does not directly affect its 4 pCi/L action level.[EPA] How the two compare is covered on EPA radon action level.

The third unit: working levels (WL)

Some reports give working levels. EPA’s risk assessment explains that radon progeny (decay product) concentrations are commonly expressed in WL.[EPA] EPA says radon test results may be reported in pCi/L, WL or Bq/m³, and that if your result is in WL, EPA recommends fixing your home at 0.016 WL or higher. Some states require WL results to be converted to pCi/L to minimize confusion.[EPA]

EPA’s risk assessment explains that each pCi/L of radon gives rise to almost precisely 0.01 WL only under equilibrium conditions, that ordinarily these conditions do not hold, and that in homes the equilibrium fraction is typically 40%.[EPA] Use EPA’s stated WL action level rather than converting a WL result yourself.

Reading a radon report in another unit: checklist

  1. Find the unit on the report: pCi/L, Bq/m³ or WL.[EPA]
  2. If Bq/m³, compare with EPA’s Bq/m³ figures: at or above 150 Bq/m³ should be reduced;[EPA] consider fixing between 75 and 150 Bq/m³.[EPA] Dividing by 37 gives pCi/L for information.[EPA]
  3. If pCi/L, compare with EPA guidance in pCi/L: fix at 4 pCi/L or higher (after a follow-up test if your first test was short-term); consider fixing between 2 and 4 pCi/L.[EPA][EPA]
  4. If WL, compare with EPA’s 0.016 WL, or ask the lab or your state radon office for a pCi/L result.[EPA]
  5. Keep WHO figures separate from EPA’s: 100 and 300 Bq/m³ are WHO reference levels.[World Health Organization]
  6. Check which test it was. EPA says a short-term test is less likely than a long-term test to tell you your year-round average.[EPA]

EPA says radon levels less than 4 pCi/L still pose a risk.[EPA] This is general information, not medical advice; talk to your doctor about health questions. For what each level means under EPA guidance, see radon levels.

Frequently asked questions

How do I convert pCi/L to Bq/m³?

Multiply by 37. EPA's Assessment of Risks from Radon in Homes says 1 picocurie equals 0.037 Bq, so 1 pCi/L corresponds to 37 Bq/m³. For example, EPA lists 10 pCi/L as 370 Bq/m³.

How do I convert Bq/m³ to pCi/L?

Divide by 37. EPA gives WHO's 100 Bq/m³ reference level as 2.7 pCi/L and 300 Bq/m³ as 8.1 pCi/L, which matches dividing by 37 and rounding to one decimal place.

Why does EPA say 4 pCi/L is 150 Bq/m³?

EPA's consumer pages show a rounded equivalent. Multiplying 4 by the exact factor of 37 gives a value slightly under 150, and EPA's pages print 150 Bq/m³ next to its 4 pCi/L action level.

Which unit does the EPA action level use?

EPA states its action level in pCi/L: fix your home at 4 pCi/L or higher. Its FAQ pages add 150 Bq/m³ and, for working-level results, 0.016 WL.

Is WHO's 100 Bq/m³ the same as EPA's 4 pCi/L?

No. EPA gives WHO's 100 Bq/m³ reference level as 2.7 pCi/L, which is lower than EPA's 4 pCi/L action level. EPA says the WHO recommendation does not directly affect its action level.

Sources

  1. U.S. Environmental Protection Agency (EPA), Office of Radiation and Indoor Air. EPA Assessment of Risks from Radon in Homes (EPA 402-R-03-003) — errata, preface, abstract and executive summary. Accessed 2026-11-25.
  2. U.S. Environmental Protection Agency (EPA), Federal Register via GPO govinfo. National Primary Drinking Water Regulations; Radon-222; Proposed Rule (64 FR 59246, November 2, 1999) — excerpts. Accessed 2026-11-25.
  3. U.S. Environmental Protection Agency (EPA). What is EPA's Action Level for Radon and What Does it Mean? (EPA Radon FAQ). Accessed 2026-11-25.
  4. U.S. Environmental Protection Agency (EPA). Health Risk of Radon. Accessed 2026-11-25.
  5. U.S. Environmental Protection Agency (EPA). Explain Working Levels (WL) and Picocuries Per Liter of Air (pCi/L) (EPA Radon FAQ). Accessed 2026-11-25.
  6. U.S. Environmental Protection Agency (EPA). Does the 2009 World Health Organization's recommendation of a lower radon action level affect the EPA's radon action level of 4 pCi/L? (EPA Radon FAQ). Accessed 2026-11-25.
  7. World Health Organization (WHO). Radon (WHO fact sheet). Accessed 2026-11-25.
  8. U.S. Environmental Protection Agency (EPA), Indoor Environments Division. A Citizen's Guide to Radon: The Guide to Protecting Yourself and Your Family from Radon (EPA 402/K-12/002). Accessed 2026-11-25.
  9. U.S. Environmental Protection Agency (EPA). What is the average level of radon found in homes in the U.S.? (EPA Radon FAQ). Accessed 2026-11-25.