Radon Mitigation System: How It Works and What You Get

A radon mitigation system is equipment installed in a home to lower its indoor radon level. EPA describes several proven methods, but the one primarily used is a vent pipe system and fan that pulls radon from beneath the house and vents it to the outside; EPA calls this a soil suction radon reduction system and says it does not require major changes to your home [EPA]. You will also see the same equipment called a radon reduction system, a radon elimination system or simply radon mitigation.

This guide covers what a radon mitigation system is, how it works, the main system types, what a finished installation must include, what it costs according to each published source, and the testing that should follow.

What is a radon mitigation system?

EPA states its “when to fix” guidance in three documents, and they are worded differently:

EPA’s reason, in its own words: “Radon is the leading cause of lung cancer for non-smokers and the second leading cause of lung cancer for the general population” [EPA]. This page is not medical advice; for health questions, talk to your doctor.

Radon gets in because the air pressure inside a home is usually lower than the pressure in the soil around the foundation, so the house acts like a vacuum and draws radon in through foundation cracks and other openings [EPA]. A mitigation system works against that pressure difference.

EPA groups methods into two kinds: techniques that prevent radon from entering, and techniques that reduce radon after it has entered. EPA generally recommends methods that prevent entry [EPA].

Radon elimination system, radon reduction system: same idea

“Elimination” overstates what any system does. EPA says any radon exposure has some risk, and that with today’s technology radon levels in most homes can be reduced to 2 pCi/L or below [EPA]. For comparison, EPA notes about 0.4 pCi/L is normally found in outside air [EPA]. EPA’s term is “radon reduction system”, and that is what all of these names describe.

How does a radon mitigation system work?

The common system, active subslab suction (also called subslab depressurization), works in a few steps [EPA]:

  1. Suction point. One or more suction pipes are inserted through the floor slab into the crushed rock or soil underneath, or below the slab from outside the home. Often only a single suction point is needed.
  2. Fan. A radon vent fan connected to the pipes draws radon from below the home and creates a negative pressure, or vacuum, beneath the slab. Common fan locations are unconditioned spaces such as attics and garages, or the exterior of the home. Being unconditioned is not enough on its own: the fan must also not be below a livable area (see the checklist below).
  3. Exhaust. The radon-containing soil gas is exhausted outdoors through a pipe that ends above the edge of the roof [Minnesota Department of Health], where it is quickly diluted.

Minnesota’s health department puts it plainly: systems use a fan to continuously pull air from the soil and vent it outdoors through a pipe that ends above the edge of the roof; the pipe can run inside or outside the home [Minnesota Department of Health].

Why the roof? EPA explains that radon concentration falls off sharply with distance from the discharge point and approaches background levels at 3-4 feet from it. EPA disallowed ground-level discharge mainly because of possible re-entry into the house and exposure of children [EPA].

For the details of each part, see sub-slab depressurization, the radon fan and the radon vent pipe.

Types of radon mitigation systems

Your foundation type shapes the choice. EPA groups homes as basement, slab-on-grade or crawlspace, and notes that many homes combine more than one, which may call for a combination of techniques [EPA]. Method choice by foundation is covered in radon mitigation by foundation type.

System Used where How it works Typical radon reduction (EPA) Fan
Subslab suction (subslab depressurization) Basement, slab-on-grade Pipe and fan pull soil gas from under the slab 50 to 99 percent Fan (active); DOE notes sub-slab depressurization may be passive or include a fan
Passive subslab suction Mostly new homes built radon-resistant Same pipe, relies on natural pressure and air currents 30 to 70 percent None, by EPA’s description
Drain-tile suction Homes with drain tiles or perforated pipe Suction on the drain tile loop 50 to 99 percent Requires a fan (DOE)
Sump-hole suction Basements with a sump Sump is capped and used as the suction point 50 to 99 percent Requires a fan (DOE)
Block-wall suction Hollow block foundation walls Depressurizes the block wall, often with subslab suction 50 to 99 percent Not in the DOE list
Submembrane depressurization Crawlspace Plastic sheet over the earth floor; pipe and fan draw from under it 50 to 99 percent Requires a fan (DOE)
Crawlspace ventilation Crawlspace Opening or adding vents, or a fan blowing air through 0 to 50 percent (natural ventilation) Passive, or active with a fan, per EPA
House or basement pressurization Any Fan blows air in to keep radon out 50 to 99 percent Uses a fan, per EPA
Heat recovery ventilation Any, best in basements Brings in outdoor air while recovering heat Variable Not in the DOE list

Sources: descriptions and reduction ranges from EPA’s Consumer’s Guide [EPA]; entries marked DOE in the fan column come from the DOE Building America Solution Center’s retrofit list [U.S. DOE Building America Solution Center], the others from EPA’s descriptions.

A few points from EPA on the less common options [EPA]:

Sealing is a helper, not a system

Sealing cracks and other openings is a basic part of most approaches, because it makes other techniques more effective and cost-efficient. But EPA does not recommend sealing alone, because by itself it has not been shown to lower radon levels significantly or consistently [EPA]. See sealing cracks for radon and the radon sump pump cover guide.

Passive or active?

A passive system has the pipe but no fan; an active system adds the fan. EPA’s table puts passive subslab suction at 30 to 70 percent and says it is not as effective as active subslab suction [EPA]. If a home with a passive system tests at 4 pCi/L or more, EPA says a qualified mitigator can add a vent fan [EPA]. See passive vs active radon mitigation.

What a finished radon mitigation system includes

Use this checklist on installation day. EPA says to verify with your contractor that radon mitigation standards are met and to check with your state radon office for any state requirements [EPA]. Rules differ by state and standard edition, so the source of each line is named.

Check What the source says
Label Systems must be clearly labeled to avoid accidental changes (EPA) [EPA]. Minnesota requires a radon tag on all systems installed by professionals [Minnesota Department of Health].
Exhaust height Above the surface of the roof and 10 feet or more above the ground (EPA) [EPA].
Exhaust distance from openings At least 10 feet from windows, doors or other openings, if the pipe does not vent at least 2 feet above them (EPA) [EPA].
Exhaust direction Upward; the 2024 AARST bulletin’s text says the discharge shall not exhaust downward [AARST Consortium on National Standards].
Fan location Not in or below a livable area; for instance, in unconditioned space (EPA) [EPA]. Both conditions apply, so by that rule an unconditioned space that sits beneath living space, such as a crawl space or unfinished basement under the house, does not qualify. The 2024 AARST bulletin’s text also rules out spaces directly beneath conditioned or occupiable space and allows garages only when they are not beneath such space [AARST Consortium on National Standards].
Outdoor fan Must meet local building codes for exterior use (EPA) [EPA].
Electrical Installed according to local electrical codes (EPA) [EPA]; Minnesota notes most installs need an electrical permit [Minnesota Department of Health].
Warning device Among EPA’s basic installation requirements that your contractor should meet for active systems, placed where it can be seen or heard; examples include a liquid gauge, a sound alarm, a light indicator and a dial gauge (EPA) [EPA].
Active alert The 2024 AARST bulletin’s text calls for a monitor that actively alerts occupants if the fan fails [AARST Consortium on National Standards].
Sump lid Where a sump is the suction point, lids sealed airtight (AARST bulletin) [AARST Consortium on National Standards].
Pipe slope Horizontal runs sloped slightly downward so water cannot be trapped (Pennsylvania DEP) [Pennsylvania Department of Environmental Protection].
Handover The contractor explains the system, shows how it operates, and gives written operating and maintenance instructions and warranty copies (EPA) [EPA].
Follow-up test Within 30 days, no sooner than 24 hours after start-up (EPA) [EPA].

Minnesota lists the typical visible parts of a finished system: the radon fan in an attic, garage or outside; a PVC radon pipe; a U-tube manometer that shows whether the fan is working; and an active notification monitor that alarms if the fan is not working properly [Minnesota Department of Health].

How much does a radon mitigation system cost?

EPA’s current guidance gives no installation price range. It says most homes can be fixed for about the same cost as other common home repairs, and that costs vary with the size and design of your home and the methods needed [EPA]. EPA’s FAQ does still say replacing a fan will cost around $200 - $350 including parts and labor, the same figure printed in its older guides [EPA].

The full table of sources, operating costs and a quote-check list are on the radon mitigation cost page.

How a radon mitigation system is installed

Kansas State University’s radon program says that for a typical single-family home the work can be done in one day by a qualified contractor [Kansas State University]. Pennsylvania DEP says installation should take less than a day [Pennsylvania Department of Environmental Protection].

Before designing the system, the contractor does a visual inspection and may run diagnostic tests, such as chemical smoke or a soil communication test, to see how air moves under the foundation [EPA]. EPA also says a contractor may raise concerns about backdrafting of combustion appliances and recommend having them checked [EPA].

Step by step, see radon mitigation system installation.

Testing after installation

The follow-up test tells you whether the system works. EPA’s rules for it [EPA]:

  1. Test within 30 days of installation, but no sooner than 24 hours after the system is running with the fan on.
  2. Use a two- to seven-day measurement.
  3. Keep windows and doors closed 12 hours before and during the test, except for normal entry and exit.
  4. The contractor may run a test, but EPA recommends an independent follow-up measurement too, either by an independent tester or by you, to avoid a conflict of interest.

North Carolina’s radon program says standard systems are usually effective within 24 hours and keep levels low as long as the fan is operating [North Carolina Department of Health and Human Services]. For results reported in studies, see do radon mitigation systems work?

After that, EPA says it is a good idea to retest at least every two years [EPA]. Retest in the lowest lived-in area after major remodeling [EPA], and on a lower level if you start using it, such as a basement [EPA].

Living with a radon mitigation system

When to call a certified professional

Who counts as qualified depends on your state:

More on vetting a contractor is in choosing a radon mitigation contractor; the limits of doing it yourself are covered in DIY radon mitigation.

Common mistakes

  1. Relying on sealing alone. EPA does not recommend it [EPA].
  2. Turning the fan off. The system only works while the fan runs [EPA].
  3. Fan in or below living space. EPA says the fan must not be located in or below a livable area [EPA]. By that rule, an unconditioned space is not automatically acceptable: a crawl space or unfinished basement beneath living space is still below a livable area.
  4. Exhaust near the ground or a window. EPA disallowed ground-level discharge [EPA], and its installation requirements keep the exhaust at least 10 feet from windows, doors or other openings unless it vents at least 2 feet above them [EPA].
  5. Skipping or rushing the follow-up test. Wait at least 24 hours, and test within 30 days [EPA].
  6. Paying in full too early. Minnesota advises getting a valid test showing reduced levels before full payment [Minnesota Department of Health]; see the quote-check list on the cost page.

Frequently asked questions

What is a radon mitigation system?

It is a system that lowers the radon level in a home. EPA says the one primarily used is a vent pipe system and fan that pulls radon from beneath the house and vents it to the outside, known as a soil suction radon reduction system.

How does a radon mitigation system work?

A fan connected to suction pipes draws radon from below the home and releases it outdoors, while creating negative pressure beneath the slab. That keeps soil gas from being drawn into the house. The exhaust must vent above the roof, away from windows and doors.

Is a radon elimination system different from a radon mitigation system?

The terms describe the same kind of system. EPA calls it a radon reduction or mitigation system, because it reduces radon rather than removing it entirely: EPA says levels in most homes can be reduced to 2 pCi/L or below with today's technology.

When does EPA recommend installing a radon mitigation system?

EPA's Consumer's Guide recommends fixing your home if one long-term test or the average of two short-term tests shows 4 pCi/L or higher; its Citizen's Guide says to consider fixing when the average of two short-term tests is 4 pCi/L or higher. EPA adds that you may also want to consider fixing if the level is between 2 and 4 pCi/L.

Can I turn the radon fan off to save electricity?

No. EPA says the fan should never be turned off; it must run continuously for the system to work correctly.

How soon after installation should I test?

EPA says a post-mitigation test should be done within 30 days of installation, but no sooner than 24 hours after the system is running with the fan on, using a two- to seven-day measurement.

Sources

  1. U.S. Environmental Protection Agency (EPA), Indoor Air Quality. Consumer's Guide to Radon Reduction: How to Fix Your Home (EPA 402/K-10/005, 2025 edition). Accessed 2026-11-25.
  2. U.S. Environmental Protection Agency (EPA), Indoor Environments Division. A Citizen's Guide to Radon: The Guide to Protecting Yourself and Your Family from Radon (EPA 402/K-12/002). Accessed 2026-11-25.
  3. U.S. Environmental Protection Agency (EPA), Indoor Environments Division. Home Buyer's and Seller's Guide to Radon (EPA 402/K-24/001, March 2024 revised). Accessed 2026-11-25.
  4. U.S. Environmental Protection Agency (EPA). Why must radon be vented into the air above my home's roof? (EPA Radon FAQ). Accessed 2026-11-25.
  5. U.S. Environmental Protection Agency (EPA). How much can a radon mitigation system cost? (EPA Radon FAQ). Accessed 2026-11-25.
  6. U.S. Environmental Protection Agency (EPA). How do I know if my radon mitigation system is working properly? (EPA Radon FAQ). Accessed 2026-11-25.
  7. U.S. Environmental Protection Agency (EPA); authors Krop, Bowles, Pawel, Roy, Malashock. Analysis of Benefits and Costs of Radon Reduction Strategies Recommended by the EPA: Cost-Effective Interventions for Lung Cancer Prevention (October 2025) — cost sections. Accessed 2026-11-25.
  8. U.S. Environmental Protection Agency (EPA). Find a Radon Test Kit or Measurement and Mitigation Professional. Accessed 2026-11-25.
  9. U.S. DOE Building America Solution Center (Pacific Northwest National Laboratory; figures by Building Science Corporation). Vertical Radon Ventilation Pipe (Building America Solution Center resource guide). Accessed 2026-11-25.
  10. AARST Consortium on National Standards (Indoor Environments Association / American Association of Radon Scientists and Technologists). Technical Bulletin: SGM-SF 2023 and SGM-MFLB 2023 Soil Gas Mitigation Standards (with redline text of ANSI/AARST SGM-MFLB-2023). Accessed 2026-11-25.
  11. Minnesota Department of Health (MDH), Indoor Air Unit. Radon Mitigation Systems (Minnesota Department of Health). Accessed 2026-11-25.
  12. Minnesota Department of Health (MDH), Indoor Air Unit. Licensing for Radon Professionals (Minnesota Department of Health). Accessed 2026-11-25.
  13. Pennsylvania Department of Environmental Protection (DEP), Radon Program staff. Nine tips for having a radon reduction system installed in your home (PA DEP blog, January 26, 2022). Accessed 2026-11-25.
  14. Pennsylvania Department of Environmental Protection (DEP), Bureau of Radiation Protection, Radon Division. Radon in the Home. Accessed 2026-11-25.
  15. Wisconsin Department of Health Services (DHS), Radon program. Radon Mitigation (Wisconsin Department of Health Services). Accessed 2026-11-25.
  16. North Carolina Department of Health and Human Services (NCDHHS), Division of Health Service Regulation, NC Radon Program. Radon Mitigation (North Carolina Radon Program, NC DHHS). Accessed 2026-11-25.
  17. Kansas State University, National Radon Program Services (sosradon.org; operates EPA's 1-800-SOS-RADON line in partnership with EPA). Reducing Radon in Your Home (National Radon Program Services, Kansas State University). Accessed 2026-11-25.
  18. Minnesota Department of Health (MDH), Indoor Air Unit. Find a Radon Mitigation Professional (Minnesota Department of Health). Accessed 2026-11-25.