Commercial Radon Testing and Mitigation: Schools, Multifamily, HUD

Commercial radon testing and mitigation follow different standards from single-family homes. Schools, apartment buildings, offices and mixed-use buildings are covered by their own ANSI/AARST standards.[EPA] This page maps those standards, summarizes what EPA says about schools, and explains the two HUD notices that touch multifamily and HUD-assisted housing. It is general information for building owners and managers; your state radon office and program guidance set the actual requirements.

Standards map by building type

EPA’s standards page lists the current ANSI/AARST standards and says each is recommended for immediate use with a compliance date of December 1st, 2023.[EPA] The AARST catalog says an ANSI/AARST standard for radon measurement and mitigation is available for every building type.[AARST Consortium on National Standards]

Building Measurement Mitigation (existing) New construction
Single-family homes ANSI/AARST MAH-2023[EPA] ANSI/AARST SGM-SF-2023[EPA] ANSI/AARST CCAH and RRNC (1 & 2 family dwellings and townhouses)[EPA]
Multifamily, school, commercial and mixed-use ANSI/AARST MA-MFLB-2023[EPA] ANSI/AARST SGM-MFLB-2023[EPA] ANSI/AARST CC-1000-2018-0523 (any building for human occupancy except 1 and 2 family dwellings)[EPA]

What each multi-unit standard covers, per EPA:

The full standards are sold or viewable through AARST; EPA’s page says they may be viewed for free and PDF copies purchased.[EPA] The detailed testing protocol for commercial buildings (number and placement of devices, test conditions) is inside MA-MFLB and is not summarized in our sources.

Schools: what EPA says

How common elevated radon is

EPA’s schools page (which gives no survey year) says a nationwide survey estimates that nearly one in five schools has at least one schoolroom with a short-term radon level above the action level of 4 pCi/L, and that more than 70,000 schoolrooms in use have high short-term radon levels.[EPA] EPA recommends that all schools nationwide be tested and says that, to date, approximately 20% of schools nationwide have done some testing.[EPA]

EPA states that radon is the second leading cause of lung cancer in the United States after smoking.[EPA] This is general information, not medical advice; talk to your doctor about health questions.

Testing schools

EPA’s basic elements are: test all frequently used rooms on and below the ground level, test in the cooler months, and follow its testing strategy.[EPA] EPA’s older school measurement guide (1993; EPA says it no longer updates it) adds:[EPA]

  1. Make initial short-term tests in all frequently occupied, ground-contact rooms.
  2. Test during the coldest months, with heating running and windows and doors closed except for normal entry and exit.
  3. For 2- to 5-day tests, test on weekdays with the HVAC system operating normally.
  4. If a room tests at 4 pCi/L or greater, confirm with a second short-term test or a long-term test; EPA does not recommend acting on a single short-term result.
  5. Include duplicates and blanks for quality assurance.

How fast to act

The same guide says very elevated levels, for example several times the action level or around 10 pCi/L, demand a quicker response, and if levels are near 100 pCi/L or greater, school officials should call their State Radon Contact and consider relocating until levels can be reduced.[EPA]

Mitigating schools

EPA’s investigations found school buildings more complex in construction and operation than most houses, so diagnostic measurements are necessary to develop a mitigation strategy.[EPA] Two strategies were found effective:[EPA]

Strategy How it works When EPA’s guide points to it
Active sub-slab depressurization (ASD) Pipes penetrate the slab or foundation walls; a high-suction fan draws soil gas from beneath the building before it enters Particularly effective above 20 pCi/L; when levels are greater than 10 pCi/L, ASD will probably be needed to get below 4 pCi/L
HVAC pressurization and ventilation Brings in enough outdoor air to create positive pressure, which can keep radon out, and dilutes radon that has entered May be more appropriate depending on building codes, occupancy, construction and initial levels; needs routine operation and maintenance and may exceed existing HVAC capacity

The guide adds that ASD should be accompanied by sealing radon entry routes, that EPA does not recommend sealing alone, and that an HVAC engineer may need to be consulted because there is no standard HVAC strategy for all schools.[EPA] When selecting a contractor, it suggests asking whether they have experience mitigating school buildings.[EPA]

Multifamily and HUD programs

Two HUD radon notices in our sources matter for multifamily and assisted housing; each HUD program office issues its own program-specific radon guidance.[HUD] They differ in scope and date.

Notice H 2013-03 (issued January 31, 2013) Notice CPD-23-103 (issued January 11, 2024)
Applies to New FHA Multifamily insured mortgage applications (MAP and TAP)[HUD] Projects subject to HUD’s contamination regulations at 24 CFR 50.3(i) or 58.5(i); not single family homes bought with an FHA-backed mortgage[HUD]
Testing Follow the ANSI-AARST multifamily protocol; test at least twenty-five percent of randomly selected ground level units[HUD] Says it does not impose radon testing requirements, but gives testing strategies[HUD]
Threshold 4.0 pCi/L[HUD] A mitigation plan is required where testing finds levels at or above 4 pCi/L[HUD]
Who does the work A Radon Professional with NRPP or NRSB certification, plus state certification or license where the state requires it[HUD] Where feasible, post-installation testing by a licensed radon professional[HUD]
Standards named ASTM E2121 (existing) and ASTM E1465 (new construction), “or most recent edition”[HUD] Refers to the applicable ANSI/AARST standards[HUD]

Notes on currency: the 2013 notice was written to supplement Chapter 9 of HUD’s Multifamily Accelerated Processing (MAP) Guide, and the 2024 notice says it does not preempt radon requirements in the MAP Guide or other Housing program guidance.[HUD][HUD] We have not verified the current MAP Guide radon chapter. Check with your HUD program contact before relying on either notice.

Under CPD-23-103, the mitigation plan must identify the radon level, describe the system, establish an ongoing maintenance plan whenever possible, set a reasonable timeframe and require post-installation testing.[HUD]

Finding qualified professionals

EPA requires states receiving indoor radon grants to list only providers credentialed through a state process or one of the two currently recognized national programs, NRPP and NRSB.[EPA] For schools and large buildings, EPA’s school guide suggests asking about experience with school buildings and consulting an HVAC specialist if an HVAC strategy is chosen.[EPA] See choosing a radon mitigation contractor for credential checks.

Cost

New buildings

For new multifamily, school and commercial construction, EPA lists ANSI/AARST CC-1000.[EPA] For one- and two-family homes, see radon-resistant new construction.

For how soil suction systems work in general, see the radon mitigation system guide.

Frequently asked questions

What standard covers commercial radon testing?

EPA lists the ANSI/AARST Protocol for Conducting Measurements of Radon and Radon Decay Products in Multifamily, School, Commercial and Mixed-Use Buildings (MA-MFLB-2023). EPA says its effective date for compliance is December 1st, 2023.

How is radon mitigated in a commercial building or school?

EPA lists ANSI/AARST SGM-MFLB-2023 as the mitigation standard for existing multifamily, school, commercial and mixed-use buildings. EPA's school guidance (1993, no longer updated) says two strategies are effective in schools: active sub-slab depressurization and pressurizing and ventilating the building with the HVAC system.

Should schools be tested for radon?

EPA recommends that all schools nationwide be tested for radon. EPA's page says a nationwide survey estimates nearly one in five schools has at least one schoolroom with a short-term radon level above 4 pCi/L.

Does HUD require radon testing?

It depends on the program. HUD's 2013 Housing Notice H 2013-03 set radon requirements for FHA multifamily mortgage insurance applications. HUD's January 2024 Notice CPD-23-103 covers HUD-assisted projects, requires a mitigation plan where radon is at or above 4 pCi/L, and states it does not apply to single family homes bought with an FHA-backed mortgage. The notice itself does not impose radon testing requirements. Check the current program guidance.

How much does commercial radon mitigation cost?

We found no EPA, HUD, state or university source with cost figures for commercial, school or multifamily radon mitigation. HUD's 2024 notice says radon testing and mitigation are eligible program costs for many HUD grant programs.

Sources

  1. U.S. Environmental Protection Agency (EPA). Radon in Schools. Accessed 2026-11-25.
  2. U.S. Environmental Protection Agency (EPA), Air and Radiation. Radon Measurement in Schools, Revised Edition (EPA 402-R-92-014, July 1993; reposted 2025) — Summary of EPA recommendations and Section III, Reducing Radon Concentrations. Accessed 2026-11-25.
  3. U.S. Environmental Protection Agency (EPA). Radon Standards of Practice (current ANSI/AARST standards and archived EPA standards). Accessed 2026-11-25.
  4. AARST Consortium on National Standards. Current ANSI/AARST American National Standards (AARST Consortium on National Standards — standards catalog page). Accessed 2026-11-25.
  5. U.S. Department of Housing and Urban Development (HUD), Assistant Secretary for Housing–Federal Housing Commissioner. Notice H 2013-03: HUD Office of Multifamily Development Radon Policy (issued January 31, 2013). Accessed 2026-11-25.
  6. U.S. Department of Housing and Urban Development (HUD), Office of Community Planning and Development. Notice CPD-23-103: Departmental Policy for Addressing Radon in the Environmental Review Process (issued January 11, 2024). Accessed 2026-11-25.
  7. U.S. Environmental Protection Agency (EPA). Find a Radon Test Kit or Measurement and Mitigation Professional. Accessed 2026-11-25.