Do Radon Mitigation Systems Work? How to Confirm Yours Does

Do radon mitigation systems work? EPA’s answer is direct: “Radon reduction systems work.” Some can reduce radon levels in a home by up to 99 percent, and hundreds of thousands of people have reduced radon levels in their homes.[EPA] What EPA cannot tell you is how well a system works in your house. That is what the post-mitigation test is for. This page covers how mitigation works, what the published figures mean, and how to check your own system.

How radon mitigation works

Air pressure inside a home is usually lower than pressure in the soil around the foundation. Because of this difference, EPA says, your home acts like a vacuum, drawing radon in through foundation cracks and other openings.[EPA]

EPA generally recommends methods that prevent radon from entering. Soil suction, for example, draws radon from below the home and vents it through a pipe, or pipes, to the air above the home where it is quickly diluted.[EPA] In active subslab suction, a radon vent fan connected to the suction pipes releases radon outdoors while creating a negative pressure, or vacuum, beneath the slab.[EPA] EPA’s homeowner guide describes the primary method the same way: a vent pipe system and fan that pulls radon from beneath the house and vents it outside, without major changes to the home.[EPA]

What the numbers say, and what each number is

Not all “effectiveness” figures are the same kind of number. This table keeps them apart.

Figure What it is Source
Up to 99 percent EPA’s statement of what some radon reduction systems can achieve EPA Consumer’s Guide (2025) and EPA FAQ[EPA][EPA]
50 to 99 percent EPA’s typical reduction for active subslab, drain-tile, sump-hole, block-wall and crawlspace submembrane suction EPA technique table (2025)[EPA]
30 to 70 percent EPA’s typical reduction for passive subslab suction (no fan) EPA technique table (2025)[EPA]
2 pCi/L or below What EPA says most homes can be reduced to with today’s technology EPA Consumer’s Guide (2025)[EPA]
1.0 pCi/L A modeling assumption for post-mitigation levels, not a measurement EPA benefit-cost report (October 2025)[EPA]
0.8 pCi/L average Field result from a Minnesota study (Steck 2008), cited by EPA EPA benefit-cost report[EPA]
0.9 pCi/L average 90 Alberta homes averaging 15.5 pCi/L before mitigation (Stanley et al. 2017), cited by EPA EPA benefit-cost report[EPA]

EPA’s report is careful about these studies: it says data on post-mitigation levels are limited, and that improvements in technology and technique may explain better results in later studies, but further research would be needed to draw definitive conclusions.[EPA] State programs make similar statements about what systems can achieve: Wisconsin DHS says mitigation systems can reduce radon to below 2 pCi/L.[Wisconsin Department of Health Services]

We did not find a national dataset showing what share of installed systems bring homes below EPA’s action level.

Why results vary from house to house

EPA lists several factors in choosing a method: how high your initial radon level is, installation and operating costs, home size and foundation type.[EPA] The method matters too: EPA’s table notes subslab suction works best when air moves easily in the material under the slab.[EPA] Our radon mitigation by foundation type page compares the methods.

How fast it works: North Carolina’s radon program says standard radon reduction systems are usually effective within 24 hours and maintain low levels as long as the fan is operating.[North Carolina Department of Health and Human Services] That last condition matters. EPA says the fan should never be turned off; it must run continuously for the system to work correctly.[EPA]

Post-mitigation test checklist

This is how you find out whether your system works. Each step is from EPA unless noted.

  1. Wait at least 24 hours. Start the test no sooner than 24 hours after the system is running with the fan on, if it has one.[EPA]
  2. Test within 30 days. EPA says the post-mitigation test should be done within 30 days of installation.[EPA] Pennsylvania DEP (2022) gives the same window: no sooner than 24 hours and before thirty days after the fan started.[Pennsylvania Department of Environmental Protection]
  3. Use a two- to seven-day test. EPA recommends a two- to seven-day measurement to test the system’s effectiveness.[EPA]
  4. Close the house. Windows and doors must be closed 12 hours before and during the test, except for normal entry and exit.[EPA]
  5. Get an independent result. The contractor may test to check the work, but EPA recommends you also get an independent follow-up measurement, by an independent tester or by doing it yourself, to eliminate any potential conflict of interest.[EPA] EPA’s buyer and seller guide likewise recommends the test be conducted by an independent, qualified radon tester.[EPA]
  6. Check the warning device works. EPA says your contractor should check that the warning device works.[EPA]
  7. Keep the paperwork. Ask for written operating and maintenance instructions and copies of any warranties.[EPA]

Reading your post-mitigation result

Result What EPA guidance says
4 pCi/L or higher EPA recommends fixing a home at this level.[EPA] Call the contractor; many contractors guarantee they will adjust or modify the system to reach a negotiated radon level, so check your contract.[EPA]
Between 2 and 4 pCi/L Below EPA’s action level. EPA says you may also want to consider fixing if the level is between 2 and 4 pCi/L.[EPA]
Below 2 pCi/L Within what EPA says most homes can reach with today’s technology. Keep retesting.[EPA]

EPA says any radon exposure has some risk of causing lung cancer, and the lower the radon level in your home, the lower your family’s risk.[EPA] This is general information, not medical advice; talk to your doctor about health questions.

Keep it working: retest

A good first result is not the end. EPA says it is a good idea to retest your home at least every two years to be sure radon levels remain low.[EPA] Pennsylvania DEP (2022) gives the same advice: even with a system in place, test every two years.[Pennsylvania Department of Environmental Protection] After remodeling, EPA says to retest in the lowest lived-in area.[EPA] The radon system maintenance guide covers the warning device and fan.

A possible side effect: drier basements

North Carolina’s program notes that reduced infiltration of moist soil air may reduce basement humidity.[North Carolina Department of Health and Human Services] An EPA contractor study (2007, revised 2008) of three Pennsylvania houses found active soil depressurization can produce significant moisture reductions in basement air and walls, and cautioned that effects may differ in other climates and house types.[EPA]

For how systems are built, see the radon mitigation system guide.

Frequently asked questions

Do radon mitigation systems really work?

EPA says radon reduction systems work and some can reduce radon levels in your home by up to 99 percent. EPA's technique table lists typical reductions of 50 to 99 percent for active soil suction methods. The only way to know your own result is a post-mitigation test.

How does radon mitigation work?

EPA explains that a home's air pressure is usually lower than the soil's, so it draws radon in through openings in the foundation. Soil suction systems reverse this: a fan and pipe draw radon from below the home and vent it above the home, where it is quickly diluted, while creating a vacuum beneath the slab.

How soon after installation does a radon system work?

North Carolina's radon program says standard radon reduction systems are usually effective within 24 hours and maintain low levels as long as the fan is operating. EPA says the post-mitigation test should start no sooner than 24 hours after the system is running with the fan on, and within 30 days of installation.

How low can radon go after mitigation?

EPA says radon levels in most homes can be reduced to 2 pCi/L or below with today's technology. EPA's 2025 benefit-cost report cites a Minnesota study that found post-mitigation levels averaging 0.8 pCi/L and an Alberta study that found an average of 0.9 pCi/L in 90 mitigated homes.

Do I still need to test after a radon system is installed?

Yes. EPA recommends a post-mitigation test within 30 days and says it is a good idea to retest at least every two years to be sure radon levels remain low. EPA also recommends an independent follow-up measurement to avoid any conflict of interest.

Sources

  1. U.S. Environmental Protection Agency (EPA), Indoor Air Quality. Consumer's Guide to Radon Reduction: How to Fix Your Home (EPA 402/K-10/005, 2025 edition). Accessed 2026-11-25.
  2. U.S. Environmental Protection Agency (EPA). How much can a radon mitigation system cost? (EPA Radon FAQ). Accessed 2026-11-25.
  3. U.S. Environmental Protection Agency (EPA), Indoor Environments Division. A Citizen's Guide to Radon: The Guide to Protecting Yourself and Your Family from Radon (EPA 402/K-12/002). Accessed 2026-11-25.
  4. U.S. Environmental Protection Agency (EPA), Indoor Environments Division. Home Buyer's and Seller's Guide to Radon (EPA 402/K-24/001, March 2024 revised). Accessed 2026-11-25.
  5. U.S. Environmental Protection Agency (EPA); authors Krop, Bowles, Pawel, Roy, Malashock. Analysis of Benefits and Costs of Radon Reduction Strategies Recommended by the EPA: Cost-Effective Interventions for Lung Cancer Prevention (October 2025) — cost sections. Accessed 2026-11-25.
  6. North Carolina Department of Health and Human Services (NCDHHS), Division of Health Service Regulation, NC Radon Program. Radon Mitigation (North Carolina Radon Program, NC DHHS). Accessed 2026-11-25.
  7. Pennsylvania Department of Environmental Protection (DEP), Radon Program staff. Nine tips for having a radon reduction system installed in your home (PA DEP blog, January 26, 2022). Accessed 2026-11-25.
  8. Wisconsin Department of Health Services (DHS), Radon program. Radon Mitigation (Wisconsin Department of Health Services). Accessed 2026-11-25.
  9. U.S. Environmental Protection Agency (EPA). How do I know if my radon mitigation system is working properly? (EPA Radon FAQ). Accessed 2026-11-25.
  10. U.S. Environmental Protection Agency, Indoor Environments Division (contractor report by Bradley Turk, Environmental Building Sciences, Inc., and Jack Hughes, Southern Regional Radon Training Center, Auburn University). Exploratory Study of Basement Moisture During Operation of ASD Radon Control Systems (Contractor Report to EPA, December 6, 2007, revised 3/10/08). Accessed 2026-11-25.