Passive vs Active Radon Mitigation: How They Compare
Passive radon mitigation means a radon vent pipe with no fan. EPA describes passive subslab suction as the same as active subslab suction except that it relies on natural pressure differentials and air currents instead of a fan to draw radon up from below the home [EPA]. An active system adds a fan to the same kind of pipe. The question for most homeowners is not which to choose from scratch, but whether a passive system already in the house is enough, and that is answered by a radon test.
Passive vs active radon systems at a glance
| Feature | Passive system | Active system |
|---|---|---|
| What moves the air | Natural pressure differences and air currents [EPA]; the DOE Building America Solution Center calls it the stack effect [U.S. DOE Building America Solution Center] | An in-line fan [U.S. DOE Building America Solution Center] |
| Typical reduction (EPA table) | 30 to 70 percent for passive subslab suction [EPA] | 50 to 99 percent for active subslab suction [EPA] |
| Other reported results | An average of about 50% in new homes (EPA, 2001) [EPA]; EPA’s 2025 model assumes passive measures reduce radon by approximately one-half (a model assumption, not a measured result) [EPA] | EPA’s 2025 model assumes homes at or above 4.0 pCi/L can be reduced to 1.0 pCi/L or lower [EPA] |
| EPA’s comment | May be more effective in cold climates; not as effective as active subslab suction [EPA] | Most common and usually the most reliable method [EPA] |
| Where you find it | Usually new homes with radon-resistant features [EPA] | Existing homes being mitigated, and new homes that tested high [EPA] |
| Electricity | No fan; EPA’s 2006 table noted there may be some energy penalties [EPA] | Fan runs continuously; MDH’s rough rule of thumb is that rated watts roughly equal yearly dollars at about $0.10 per kWh (MDH’s 2023 example price, not a current rate), so a 66-watt fan costs about $66 per year [Minnesota Department of Health] |
| Warning device | EPA’s warning-device item is written for active systems [EPA] | EPA’s basic installation requirements, which your contractor should meet, include a warning device to alert you if an active system stops working [EPA] |
| Maintenance | Label the vent system [EPA] and test after occupancy [EPA]; no fan to replace | Check the warning device regularly; fans may last five years or more [EPA] |
EPA’s overall judgment: passive subslab suction is generally not as effective in reducing high radon levels as active subslab suction [EPA]. Minnesota’s health department puts it more simply: an active system is better at removing radon than a passive system [Minnesota Department of Health].
How a passive radon system works
Passive systems are usually built in during construction. EPA lists the basic radon-resistant features of a new home [EPA]:
- Gas-permeable layer, often a 4-inch layer of clean gravel, beneath the slab so soil gas can move freely.
- Plastic sheeting on top of the gravel and under the slab; in crawl spaces, sheeting with sealed seams over the floor.
- Sealing and caulking of below-grade openings.
- Vent pipe, a 3- or 4-inch PVC or other gas-tight pipe from the gravel layer through the house to the roof.
- Junction boxes: one in the attic so a vent fan can be wired in later, and one in the living space for a fan alarm.
EPA says these passive features make it easier and less expensive to reduce radon further if they don’t bring levels below 4 pCi/L [EPA]. Minnesota has required new homes to be built radon-resistant since 2009, with a vent pipe but no fan [Minnesota Department of Health].
When EPA says to switch from passive to active
EPA says every new home should be tested after occupancy, even if it was built radon-resistant. If radon levels are still in excess of 4 pCi/L, the passive system should be activated by having a qualified mitigator install a vent fan [EPA]. EPA’s home buyer’s guide says the same about a test result of 4 pCi/L or more [EPA].
Builder programs sometimes go further. The DOE Building America Solution Center’s guidance says to install an active system with a fan if the home is in EPA Radon Zone 1 or tests at 4 picocuries/liter or more after construction, and a passive system in Zones 2 or 3 [U.S. DOE Building America Solution Center]. It also notes that EPA recommends, but does not require, that homes in Zone 1 be built radon-resistant and pre-emptively include a fan [U.S. DOE Building America Solution Center]. EPA’s zone maps predict potential indoor radon levels by county [EPA], and EPA says every new home should be tested after occupancy [EPA], so your own test result is what decides.
What a passive vent needs so a fan can be added
EPA’s 2001 builder guide lists what to plan for when the pipe goes in [EPA]:
- The fan cannot be inside the living space or in the crawlspace beneath the home; attics or garages are most common, unless there is living space above the garage.
- The fan needs a 30-inch vertical run of pipe and an unswitched electrical junction box.
- 4-inch pipe is preferred: passive systems tend to function better with it, and it allows a quieter system once activated.
- The pipe should be labeled on each floor level.
The 2024 AARST bulletin’s text adds that any system with a fan must include a monitor that actively alerts occupants if the fan fails [AARST Consortium on National Standards].
Cost: passive vs active
| Item | Figure as published | Source and date |
|---|---|---|
| Radon-resistant new construction, cost to builder | Typically between $250 and $750 | EPA web page, cost year not stated [EPA] |
| Passive measures in new construction | $619 | EPA benefit-cost model, October 2025: national-average model input in 2023 dollars, from 1990s cost data adjusted for inflation; not a price [EPA] |
| Installing the initial fan in new construction | $476 | EPA benefit-cost model, October 2025: national-average model input in 2023 dollars, from 1990s cost data adjusted for inflation; not a price [EPA] |
| Adding a vent fan to an existing passive system | About $300 | EPA Consumer’s Guide, 2010 edition, superseded [EPA] |
| Passive subslab suction, contractor installation (2006 table) | $550 - 2250 | EPA Consumer’s Guide, 2006 edition, superseded [EPA] |
| Active subslab suction, contractor installation (2006 table) | $800 - 2500 | EPA Consumer’s Guide, 2006 edition, superseded [EPA] |
EPA’s current home-building page says a radon control system is an inexpensive addition to the total cost of a house in Zone 1 [EPA]. For current retrofit figures by state, see the radon mitigation cost page.
Which one is right for your home?
- Existing home, tested at 4 pCi/L or higher: EPA calls active subslab suction the most common and usually the most reliable method [EPA]; see active soil depressurization.
- New home with a passive vent: test after you move in. If the result is 4 pCi/L or more, have a qualified mitigator add a fan [EPA].
- Passive vent, result below 4 pCi/L: keep testing. EPA says levels below 4 pCi/L still pose a risk and in many cases may be reduced [EPA]. This is not medical advice; for health questions, talk to your doctor.
For how both types fit into the full system, see the radon mitigation system guide, and for fan details, the radon fan page.
Frequently asked questions
What is a passive radon system?
It is a vent pipe system without a fan, usually built into new homes as part of radon-resistant construction. EPA says it relies on natural pressure differentials and air currents instead of a fan to draw radon up from below the home.
Does passive radon mitigation work?
It can lower radon, but less than an active system. EPA's table gives 30 to 70 percent for passive subslab suction, and EPA's 2001 builder guide says passive systems reduce radon by an average of about 50%.
When should a passive radon system be made active?
EPA says every new home should be tested after occupancy, even if built radon-resistant, and that if levels are 4 pCi/L or more, a qualified mitigator should install a vent fan to activate the passive system.
Does a passive radon vent use electricity?
A passive vent has no fan, so it has no fan electricity cost. EPA's 2006 cost table noted there may be some energy penalties for passive subslab suction.
Is an active radon system always better?
EPA says an active system is more effective at reducing high radon levels, and Minnesota's health department says an active system is better at removing radon than a passive one. A fan adds electricity cost and needs a warning device.
Sources
- U.S. Environmental Protection Agency (EPA), Indoor Air Quality. Consumer's Guide to Radon Reduction: How to Fix Your Home (EPA 402/K-10/005, 2025 edition). Accessed 2026-11-25.
- U.S. Environmental Protection Agency (EPA), Office of Air and Radiation. Consumer's Guide to Radon Reduction: How to Fix Your Home (EPA 402-K-06-094, Revised December 2006) — SUPERSEDED edition, cost passages and cost table. Accessed 2026-11-25.
- U.S. Environmental Protection Agency (EPA). Consumer's Guide to Radon Reduction: How to Fix Your Home (EPA 402/K-10/005, September 2010) — SUPERSEDED edition, fan-cost passages. Accessed 2026-11-25.
- U.S. Environmental Protection Agency (EPA), Indoor Environments Division. A Citizen's Guide to Radon: The Guide to Protecting Yourself and Your Family from Radon (EPA 402/K-12/002). Accessed 2026-11-25.
- U.S. Environmental Protection Agency (EPA), Indoor Environments Division. Home Buyer's and Seller's Guide to Radon (EPA 402/K-24/001, March 2024 revised). Accessed 2026-11-25.
- U.S. Environmental Protection Agency (EPA), Office of Air and Radiation. Building Radon Out: A Step-by-Step Guide on How to Build Radon-Resistant Homes (EPA/402-K-01-002, April 2001) — selected pages. Accessed 2026-11-25.
- U.S. Environmental Protection Agency (EPA); authors Krop, Bowles, Pawel, Roy, Malashock. Analysis of Benefits and Costs of Radon Reduction Strategies Recommended by the EPA: Cost-Effective Interventions for Lung Cancer Prevention (October 2025) — cost sections. Accessed 2026-11-25.
- U.S. Environmental Protection Agency (EPA). Radon-Resistant New Construction for Home Buyers. Accessed 2026-11-25.
- U.S. Environmental Protection Agency (EPA). How to Address Radon When Building a New Home. Accessed 2026-11-25.
- U.S. DOE Building America Solution Center (Pacific Northwest National Laboratory; figures by Building Science Corporation). Radon Fan (Building America Solution Center resource guide). Accessed 2026-11-25.
- U.S. DOE Building America Solution Center (Pacific Northwest National Laboratory; figures by Building Science Corporation). Vertical Radon Ventilation Pipe (Building America Solution Center resource guide). Accessed 2026-11-25.
- Minnesota Department of Health (MDH), Indoor Air Unit. Radon Resistant New Construction (Minnesota Department of Health). Accessed 2026-11-25.
- Minnesota Department of Health (MDH), Indoor Air Unit. Calculating Energy Costs for Mitigation Systems (with rated wattage of common radon fans). Accessed 2026-11-25.
- AARST Consortium on National Standards (Indoor Environments Association / American Association of Radon Scientists and Technologists). Technical Bulletin: SGM-SF 2023 and SGM-MFLB 2023 Soil Gas Mitigation Standards (with redline text of ANSI/AARST SGM-MFLB-2023). Accessed 2026-11-25.